Verification Stability of Anion-Exchange Membrane with Surface Modification with Application in Electrodialysis Process

Authors

  • Lucie Zárybnická
    Affiliation
    VSPJ, Jihlava, Czech Republic; Institute of Chemistry and Technology of Macromolecular Materials, Faculty of Chemical Technology, University of Pardubice, Czech Republic
  • Eliska Stranska
    Affiliation
    MemBrain s.r.o., Stráž pod Ralskem, Czech Republic
https://doi.org/10.3311/PPch.11522

Abstract

The present work deals with verification stability of the prepared anion-exchange membrane with surface modification in the time. The surface modification of a commercial ultrafiltration poly(ethersulfone) membrane was carried out graft polymerization. Poly(styrene-co-divinylbenzene-co-4-vinylbenzylchloride) surface layer was covalently attached onto commercial ultrafiltration support layer. The membrane was tested from the point of view of water content, ion-exchange capacity, specific resistance, permselectivity, FT-IR spectroscopy and SEM analysis. The tested characteristics (IEC, permselectivity, resistances, structure) of the prepared membrane were same after one year from preparation. The prepared membranes can find use in electrodialysis processes.

Keywords:

anion-exchange membrane, surface modification, graft polymerization, stability verification

Citation data from Crossref and Scopus

Published Online

2018-02-16

How to Cite

Zárybnická, L., Stranska, E. “Verification Stability of Anion-Exchange Membrane with Surface Modification with Application in Electrodialysis Process”, Periodica Polytechnica Chemical Engineering, 63(1), pp. 51–56, 2019. https://doi.org/10.3311/PPch.11522

Issue

Section

Articles